Mk 3 - 1990 to 1993

Mk 3 - 1990 to 1993

An Electric Aga usually has two electrical isolating switches located adjacent to the cooker, but perhaps hidden in a cupboard. One will probably be larger than the other, but both must be on, before the Aga will work properly.

The larger, external isolating switch will provide power to the Aga, energising its controls and allowing a minimum temperature to be achieved after several hours.

The smaller, external isolating switch controls a ‘signal’ circuit, which is energised only during periods when cheap rate electricity is available, normally during the night with perhaps a short boost during the day. During the ‘cheap rate’ period, the Aga is allowed to reach its full working temperature.

Turn the Thermostat Control Knob to the no. 5 position. The ‘Peak’Light should illuminate and will remain on until the minimum stored heat temperature is reached. It will then light up periodically, as heat is taken from the store, automatically maintaining a minimum temperature. The ‘Overnight’ light will only illuminate when ‘cheap rate’ or ‘off peak’ electricity is available.

The ‘Cheap Rate’ period may be determined by several means.

1. A Signal received by the Aga from the electricity meter, where there will either be a time clock or ‘teleswitch’
No adjustments can be made to this system, other than by the Electricity supply authority.

2. A timeclock contained internally in the Aga.
If this does not provide a cheap rate period within each 24 hour period, or if it is out of step with the known period provided by the electricity supply authority, please call your Aga service engineer for attention.

3. A small timeclock fitted external to the Aga.
This should be set to match the timed periods of cheap rate electricity offered by your supply company.

It will take at least 24 hours for the Aga to stabilise to normal temperatures.

The red, fault indicator, illuminates if an internal malfunction occurs. There is no need to turn your Aga off, but you should notify your Aga service engineer immediately.

Both the Roasting oven and the simmering/baking ovens are vented to outside atmosphere by means of a small electric fan. This is operated by the oven vent fan switch.

  • The Aga operates by releasing controlled amounts of stored heat from its brick store, using hot air distributed by an electric circulating fan.
  • This ensures that the different cooking areas of the Aga are always at their correct temperatures and ready to go.
  • The functions of the oven temperature thermostat, should not be confused with the Heat Indicator (Thermometer). The latter indicates the amount of heat stored in the castings, not actual oven temperature. When cooking is carried out, then the ‘heat store’ is robbed and the indicator will drop, taking several hours to stabilise back to the centre line.
  • Adjustments to the thermostat position should only be made in small stages. 24 hours should be allowed for the effects to take place. Observe the indicator first thing in the morning, before any cooking is carried out, to judge if the correct thermostat setting has been found. Don’t keep changing the setting, let it do its job automatically. If you are going to carry out a heavy amount of cooking, the thermostat may be turned up temporarily, to increase the amount of stored heat. A setting of 5 is probably sufficient to achieve optimum performance.
 