This section
Other Sections
|
|
Turning your Aga on - Gas
Mk 3 Burner (SIT)
| 1 |
Set control knob 2 to
Off, then turn on the gas inlet valve
1 (use a screwdriver or coin. Slot
should be in line with the pipe). Switch on
electrical supply ( where provided) |
| 2 |
Turn
control knob 2 anti clockwise to the
* position and push firmly down. At
the same time, push ignitor button 3
several times, until the pilot flame can be seen
to light, through the viewing window
4 |
| 3 |
Continue
to hold control knob firmly down for at least 30
seconds, then release. If pilot goes out, wait at
least 3 minutes before repeating procedure, this
time holding down for a little longer. |
| 4 |
When
the pilot has been successfully established turn
knob to low fire position. The main burner should
light. |
| 5 |
Leave
knob in low fire position for at least 10
minutes, before turning it anti-clockwise into
the normal run position. ( approximately centre
of green band) |
| |
 |
If
problems persist, please call your Aga service engineer.
|