Mk 3 Burner (SIT)

1 Set control knob ‘2’ to ‘Off’, then turn on the gas inlet valve ‘1’ (use a screwdriver or coin. Slot should be in line with the pipe). Switch on electrical supply ( where provided)
2 Turn control knob ‘2’ anti clockwise to the ‘*’ position and push firmly down. At the same time, push ignitor button ‘3’ several times, until the pilot flame can be seen to light, through the viewing window ‘4’
3 Continue to hold control knob firmly down for at least 30 seconds, then release. If pilot goes out, wait at least 3 minutes before repeating procedure, this time holding down for a little longer.
4 When the pilot has been successfully established turn knob to low fire position. The main burner should light.
5 Leave knob in low fire position for at least 10 minutes, before turning it anti-clockwise into the normal run position. ( approximately centre of green band)
 

If problems persist, please call your Aga service engineer.

 