This section
Other Sections
|
|
Turning your Aga on - Gas
Mk 2 Burner
Refer to the sketch below to identify the
various controls.
| 1 |
Before lighting ensure the gas valve
knob 4 is set to the OFF
position (O symbol) |
| 2 |
Turn
on gas supply externally and at internal service
tap 1, i.e finger grip in line with
pipe. |
| 3 |
Press
and hold the square button down 5 (
with flame symbol on) and with the other hand
press the round ignition button 2
several times, until the pilot flame can be seen
to be lit. |
| 4 |
Continue
holding the square button down for at least 30
seconds. |
| 5 |
Release
square button and pilot should remain alight. If
it goes out, wait 3 minutes and repeat operation,
but hold the square button down for a longer
period. |
| 6 |
With
the pilot established, rotate the control knob
anti-clockwise to the No.1 position, when the
main burner should ignite. |
| 7 |
Leave
in No.1 position for about 1 hour, then slowly
turn knob to No. 5 position, which should give
the correct amount of stored heat. |
| 8 |
Note
that if the ignitor fails the pilot flame can be
lit with a match or taper, after first removing
the inspection window. Replace window before
turning main burner on. |
| |
 |
If
problems persist, please call your Aga service engineer.
|