Home Page
 

  Previous Page Next Page
   

This section

Specific by fuel type


Other Sections

General questions

Installation and site requirements

 

Turning your Aga on - Gas
Mk 2 Burner

Refer to the sketch below to identify the various controls.

1 Before lighting ensure the gas valve knob ‘4’ is set to the ‘OFF’ position (‘O’ symbol)
2 Turn on gas supply externally and at internal service tap ‘1’, i.e finger grip in line with pipe.
3 Press and hold the square button down ‘5’ ( with flame symbol on) and with the other hand press the round ignition button ‘2’ several times, until the pilot flame can be seen to be lit.
4 Continue holding the square button down for at least 30 seconds.
5 Release square button and pilot should remain alight. If it goes out, wait 3 minutes and repeat operation, but hold the square button down for a longer period.
6 With the pilot established, rotate the control knob anti-clockwise to the No.1 position, when the main burner should ignite.
7 Leave in No.1 position for about 1 hour, then slowly turn knob to No. 5 position, which should give the correct amount of stored heat.
8 Note that if the ignitor fails the pilot flame can be lit with a match or taper, after first removing the inspection window. Replace window before turning main burner on.
 

If problems persist, please call your Aga service engineer.

 
  Previous Page Next Page