Home Page
 

  Previous Page Next Page
   

This section

Specific by fuel type


Other Sections

General questions

Installation and site requirements

 

Turning your Aga on - Gas
Mk 1 Burner

Refer to the sketch below to identify the various controls.

1 Make sure that the black control knob ‘4’ (in the centre of the numbered ring ‘5’) is in the off position. (i.e.finger grip at right angles to gas pipes)
2 Turn gas service cock ‘1’ on (i.e. with mark on cock in line with gas pipe)
3 Press and hold in, red button ‘2’, whilst repeatedly pushing or pulling as appropriate the remote ignitor ‘3’, until the pilot flame ‘6’ can be seen to be lit.
4 Continue holding red button ‘2’ in for at least 30 seconds before releasing.
5 With pilot established, turn thermostat numbered ring ‘5’ to lowest position and turn on the black control knob’4’ through 90 degrees. Main burner should light.
6 If pilot does not stay alight when releasing red button, wait 3 minutes and then repeat procedure, but holding red button in for a slightly longer period.
7 If ignitor fails, the pilot can be manually lit with a match or taper, after removing the viewing window ‘6’. Replace glass before turning on main burner.
8 After approximately 1 hour, the thermostat ring can be turned to its normal position of about no.4
 

If problems persist, please call your Aga service engineer.

 